Hirschmann GRS106-16TX/14SFP-2HV-3AUR Switch
Tlhaloso e Khutšoanyane:
Moralo o feto-fetohang oa li-switches tsa GREYHOUND 105/106 o etsa hore sena e be sesebelisoa sa marang-rang se nang le bopaki ba nako e tlang se ka fetohang hammoho le bandwidth ea marang-rang le litlhoko tsa matla. Ka ho tsepamisitse maikutlo holim'a ho fumaneha ha marang-rang tlas'a maemo a indasteri, li-switches tsena li u nolofalletsa ho khetha palo le mofuta oa sesebelisoa - esita le ho u fa bokhoni ba ho sebelisa letoto la GREYHOUND 105/106 e le sesebelisoa sa mokokotlo.
Lintlha tsa Sehlahisoa
Li-tag tsa Sehlahisoa
Letsatsi la Khoebo
Sehlahisoatlhaloso
Mofuta | GRS106-16TX/14SFP-2HV-3AUR (Khoutu ea sehlahisoa: GRS106-6F8F16TSGGY9HHSE3AURXX.X.XX) |
Tlhaloso | GREYHOUND 105/106 Series, Managed Industrial Switch, moralo o se nang fan, 19" rack mount, ho latela IEEE 802.3, 6x1/2.5/10GE +8x1/2.5GE +16xGE Design |
Software Version | HiOS 9.4.01 |
Nomoro ea Karolo | 942287016 |
Mofuta oa boema-kepe le bongata | Maemo a 30 ka kakaretso, 6x GE/2.5GE/10GE SFP(+) slot + 8x GE/2.5GE SFP slot + 16x FE/GE TX ports |
Hape Li-interface
Khokahano ea phepelo ea motlakase/ho tšoaea | Kenyelletso ea phepelo ea motlakase 1: Plug ea IEC, Khokahano ea lets'oao: 2 pin plug-in block block , Phepelo ea motlakase 2: Plug ea IEC |
Slot ea karete ea SD | 1 x slot ea karete ea SD ho hokela adaptara ea auto configuration ACA31 |
USB-C | 1 x USB-C (moreki) bakeng sa tsamaiso ea lehae |
Marang-rang boholo - bolelele of thapo
Lihlopha tse sothehileng (TP) | 0-100 m |
Fiber ea mofuta o le mong (SM) 9/125 µm | bona li-module tsa SFP |
Fibre ya mofuta o le mong (LH) 9/125 µm (transceiver e hulang nako e telele) | bona li-module tsa SFP |
Multimode fiber (MM) 50/125 µm | bona li-module tsa SFP |
Multimode fiber (MM) 62.5/125 µm | bona li-module tsa SFP |
Marang-rang boholo - cascadibility
Mola - / naleli topology | leha e le efe |
Matladitlhoko
Voltage e sebetsang | Kenyelletso ea phepelo ea matla 1: 110 - 240 VAC, 50 Hz - 60 Hz , Phepelo ea matla 2: 110 - 240 VAC, 50 Hz - 60 Hz |
Tšebeliso ea matla | Yuniti ea mantlha e nang le matla a le mong. 35W |
Phallo ea matla ho BTU (IT)/h | max. 120 |
Software
Ho fetoha | Thuto ea VLAN e Ikemetseng, Botsofali bo Potlakileng, Kenyelletso ea Aterese ea Static Unicast / Multicast, QoS / Tlhokomelo ea Boema-kepe (802.1D/p), TOS/DSCP Preoritization, Interface Trust Mode, CoS Queue Management, Queue-Shaping / Max. Lethathamo la Bandwidth, Phallo ea Phallo (802.3X), Egress Interface Shaping, Ingress Storm Protection, Jumbo Frames, VLAN (802.1Q), VLAN e sa lemoheng Mokhoa, GARP VLAN Registration Protocol (GVRP), Voice VLAN, GARP Multicast Registration Protocol (GMoping) , VLAN/vMP3 SternoRP, IGLAN/vMP3 Multicast Filtering, Multiple VLAN Registration Protocol (MVRP), Multiple MAC Registration Protocol (MMRP), Multiple Registration Protocol (MRP) , IP Ingress DiffServ Classification and Policing, IP Egress DiffServ Classification and Policing, Protocol-based VLAN, MAC-based VLAN, MAC-based VLAN. |
Khalefo | HIPER-Ring (Ring Switch), Link Aggregation with LACP, Link Backup, Media Redundancy Protocol (MRP) (IEC62439-2), RSTP 802.1D-2004 (IEC62439-1), RSTP Guards , VRRP, VRRP Tracking, HimentsVRRP (VRRP) |
Tsamaiso | Dual Software Image Support, TFTP, SFTP, SCP, LLDP (802.1AB), LLDP-MED, SSHv2, HTTP, HTTPS, IPv6 Management, Traps, SNMP v1/v2/v3, Telnet , DNS Client, OPC-UA Server |
Diagnostics | Tlhokomelo ea Khohlano ea Aterese ea Tsamaiso, Tsebiso ea MAC, Khokahano ea Lets'oao, Pontšo ea Boemo ba Sesebelisoa, TCPDump, li-LED, Syslog, Ho Rengoa ho Tsoelang Pele ho ACA, Tlhokomelo ea Boema-kepe ka Auto-Disable, Khokahano ea Flap ea ho lemoha, ho lemoha ho feteletseng, Duplex Mismatch Detection, Link Speed le Duplex Monitoring, Mirror Port, 19, RMON,19 Mirroring 8:1, Port Mirroring N:1, Port Mirroring N:2, Information System, Boitlhahlobo ka Cold Start, Copper Cable Test, SFP Management, Configuration Check Dialog, Switch Dump , Email Notification, RSPAN, SFLOW, VLAN Mirroring , Tlhokomeliso ea Khohlano ea Aterese bakeng sa likhokahano tsa litsela. |
Tlhophiso | Phetoho e Ikemetseng (Roll-back), Configuration Fingerprint, Text-based Configuration File (XML), Backup config ho server e hole ha u boloka, Hlakola config empa boloka li-setting tsa IP, BOOTP/DHCP Client e nang le Auto-Configuration, DHCP Server: per Port, DHCP Server: Pools per VLAN, ACADiscover card, ACADiscover. Fetisetsa ka Option 82, Command Line Interface (CLI), CLI Scripting, CLI script e sebetsanang le ENVM boot, Tšehetso e feletseng ea MIB, Thuso e Senyehileng ka Moelelo, Tsamaiso ea HTML5 e thehiloeng. |
Tshireletso | Ts'ireletso ea Port e thehiloeng ho MAC, Port-based Access Control e nang le 802.1X, VLAN ea Baeti / e sa netefatsoang, Seva e Kopanetsoeng ea Tiiso (IAS), RADIUS VLAN Assignment, Denial-of-Service Prevention, VLAN-based ACL, Ingress VLAN-based ACL, Basic ACL, Access to Management e Thibeloa ke Tsela ea Ts'ireletso ea VLI, Taolo ea Setifikeiti sa HTTPS, phihlello e thibetsoeng ea taolo, Banner ea Tšebeliso e Nepahetseng, Leano la Password la Configurable, Nomoro e Lokeloang ea Maiteko a ho Kena, Ho rema lifate tsa SNMP, Maemo a Tloaelehileng a Mangata, Tsamaiso ea Basebeletsi ba Lehae, netefatso e hole ka RADIUS, Ho notlela Ak'haonte ea Mosebelisi, Phetoho ea phasewete ha u kena ka lekhetlo la pele, Kabelo ea Leano la RADIUS, Kabelo ea Leano la MAC, Aupass Likhetho tsa Format bakeng sa ho feta ha netefatso ea MAC, DHCP Snooping, IP Source Guard, Dynamic ARP Inspection, LDAP, Ingress MAC-based ACL, Egress MAC-based ACL, Ingress IPv4-based ACL, Egress IPv4-based ACL, ACL e thehiloeng nako, Egress VLAN-based ACL, ACL Flow. |
Kamahanyo ya nako | PTPv2 Transparent Clock mehato e 'meli, PTPv2 Boundary Clock, BC e nang le ho fihla ho 8 Sync / s , Buffered Real Time Clock, Client SNTP, SNTP Server |
Litaba tsa indasteri | EtherNet / IP Protocol Modbus TCP PROFINET Protocol |
Tse fapaneng | Manual Cable Crossing, Port Power Down |
Ho tsamaisa tsela | IP/UDP Helper, Full Wire-Speed Routing, Port-based Router Interfaces, VLAN-based Router Interfaces, Loopback Interface, ICMP Filter, Net-directed Broadcasts, OSPFv2, RIP v1/v2, ICMP Router Discovery (IRDP), Static Unicast Routing, Proxy Route Tracking, ARP |
Multicast routing | IGMP v1/v2/v3, IGMP Proxy (Multicast Routing) |
Ambientmaemo
Mocheso oa ho sebetsa | -10 - +60 |
Hlokomela | 1 013 941 |
Mocheso oa polokelo / oa lipalangoang | -20 - +70 °C |
Mongobo o amanang (o sa nyenyefatseng) | 5-90 % |
Mechini kaho
Litekanyo (WxHxD) | 444 x 44 x 355 limilimithara |
Boima ba 'mele | 5 kg e hakanyetsoa |
Ho phahamisa | Sebaka sa marang-rang |
Sehlopha sa tšireletso | IP30 |
Hirschmann GRS 105 106 Series GREYHOUND Switch Mehlala e Fumanehang
GRS105-16TX/14SFP-2HV-3AUR
GRS105-24TX/6SFP-1HV-2A
GRS105-24TX/6SFP-2HV-2A
GRS105-24TX/6SFP-2HV-3AUR
GRS106-16TX/14SFP-1HV-2A
GRS106-16TX/14SFP-2HV-2A
GRS106-16TX/14SFP-2HV-3AUR
GRS106-24TX/6SFP-1HV-2A
GRS106-24TX/6SFP-2HV-2A
GRS106-24TX/6SFP-2HV-3AUR
Lihlahisoa tse amanang
-
Hirschmann MM2-4TX1 - Media Module Bakeng sa MI...
Tlhaloso Tlhaloso ea Sehlahisoa MM2-4TX1 Nomoro ea Karolo: 943722101 Ho ba teng: Letsatsi la ho Qetela: La 31 Tšitoe, 2023 Mofuta oa boema-kepe le bongata: 4 x 10/100BASE-TX, thapo ea TP, li-sockets tsa RJ45, auto-crossing, auto-negotiation, auto-polarity litlhoko tsa TP0 Power Network size Opereishene Voltage: phepelo ea motlakase ka mokokotlo oa phetoho ea MICE Tšebeliso ea matla: 0.8 W Phallo ea matla ...
-
Hirschmann SPR20-8TX-EEC Phetoho e sa Laoleheng
Letsatsi la Khoebo Tlhaloso ea Sehlahisoa Ha e laoloe, Industeri ea ETHERNET Rail Switch, moralo o se nang fene, mokhoa oa ho boloka le ho fetela pele, sebopeho sa USB bakeng sa tlhophiso , Mofuta oa Port Ethernet Port le bongata 8 x 10/100BASE-TX, thapo ea TP, li-sockets tsa RJ45, auto-crossing, auto-negotiation, auto-polarity plugin Power/ Interface block, auto-polarity Khokahano ea 6-pin ea USB 1 x USB bakeng sa tlhophiso...
-
Hirschmann OCTOPUS-5TX EEC Supply Voltage 24 VD...
Selelekela OCTOPUS-5TX EEC ha e laoloe IP 65 / IP 67 switjha ho latela IEEE 802.3, lebenkele-le-pele-switching, Fast-Ethernet (10/100 MBit/s) likoung, motlakase Fast-Ethernet (10/100 MBit/s) M12-likoung Tlhaloso ea Sehlahisoa Mofuta oa ECTOPUS Outdoor appl...
-
Hirschmann SPIDER-PL-20-24T1Z6Z699TZ9HHHV Motho...
Tlhaloso ea Sehlahisoa Sehlahisoa: SPIDER-PL-20-24T1Z6Z699TZ9HHHV Configurator: SPIDER-PL-20-24T1Z6Z699TZ9HHHV Tlhaloso ea Sehlahisoa Ha e laoloe, Industrial ETHERNET Rail Switch, moralo o se nang fene, boloka le mokhoa oa ho fetisetsa pele, USB interface bakeng sa tlhophiso 13 Nomoro ea Ethernet 19 Fast Ethernet Part4 Ethernet mofuta le bongata 24 x 10/100BASE-TX, thapo ea TP, li-sockets tsa RJ45, ho tšela ka borona, puisano ea boiketsetso, ...
-
HIRSCHCHMANN RSPE35-24044O7T99-SCCZ999HHME2AXX....
Selelekela Li-switch tsa RSPE tse kopaneng le tse matla haholo li na le sesebelisoa sa mantlha se nang le likou tse peli tse sothehileng le likou tse 'ne tse kopaneng tse tšehetsang Fast Ethernet kapa Gigabit Ethernet. Sesebelisoa sa mantlha - se fumanehang ka boikhethelo le HSR (High-Availability Seamless Redundancy) le PRP (Parallel Redundancy Protocol) liprothokholo tsa ho fokotsa boteng tse sa senyeheng, hammoho le khokahano e nepahetseng ea nako ho latela IEEE ...
-
Hirschmann GMM40-OOOOOOOOSV9HHS999.9 Media Modu...
Tlhaloso ea Sehlahisoa Tlhaloso GREYHOUND1042 Gigabit Ethernet media module Mofuta oa boema-kepe le bongata 8 likoung FE / GE; 2x FE / GE SFP slot ; 2x FE / GE SFP slot ; 2x FE / GE SFP slot ; 2x FE / GE SFP slot Saese ea marang-rang - bolelele ba cable Fibre mode e le 'ngoe (SM) 9/125 µm port 1 le 3: bona li-module tsa SFP; port 5 le 7: bona li-module tsa SFP; port 2 le 4: bona li-module tsa SFP; port 6 le 8: bona li-module tsa SFP; Fiber ea mofuta o le mong (LH) 9/...