• hlooho_banner_01

Hirschmann DRAGON MACH4000-52G-L3A-MR Switch

Tlhaloso e Khutšoanyane:

Fetola Gigabit Ethernet Backbone Switch e fihlang ho 48x GE + 4x 2.5/10 GE port, modular design, fan unit e kentsoe, liphanele tse foufetseng bakeng sa karete ea mohala le lisebelisoa tsa motlakase li kenyelelitsoe, likarolo tse tsoetseng pele tsa Layer 3 HiOS, litsela tse ngata


Lintlha tsa Sehlahisoa

Li-tag tsa Sehlahisoa

Letsatsi la Khoebo

 

Sehlahisoatlhaloso

Mofuta: DRAGON MACH4000-52G-L3A-MR
Lebitso: DRAGON MACH4000-52G-L3A-MR
Tlhaloso: Fetola Gigabit Ethernet Backbone Switch e nang le likou tse fihlang ho 52x GE, moralo oa modular, fan unit e kentsoe, liphanele tse foufetseng bakeng sa karete ea mohala le lisebelisoa tsa phepelo ea motlakase li kenyellelitsoe, likarolo tse tsoetseng pele tsa Layer 3 HiOS, litsela tse ngata
Software Version: HiOS 09.0.06
Nomoro ea Karolo: 942318003
Mofuta oa boema-kepe le bongata: Likou ka kakaretso li fihla ho 52, Likou tsa motheo tsa 4 tse tsitsitseng: 4x GE SFP, Modular: 48x FE / GE likoung tse atolositsoeng ka li-module tse 'nè tsa mecha ea litaba, li-ports tsa 12x FE / GE ka module.

 

Hape Li-interface

V.24 segokahanyi: 1 x RJ45 sokete
Slot ea karete ea SD: 1 x ho hokela adaptara ea auto-configuration ACA31 (SD)
Sehokelo sa USB: 1 x USB ho hokela adaptara ea boiketsetso ea ACA22-USB

 

Matladitlhoko

Voltage e sebetsang:

PSU unit input: 100 - 240 V AC; switjha e ka sebetsoa ka li-unit tsa PSU tse 1 kapa tse peli (tse tla odara ka thoko)

Tšebeliso ea matla:

80 W (ho kenyeletsoa li-transceivers tsa SFP + 1 PSU + Fan module)

 

Software

  

Fetoha:

Ho Ithuta ka VLAN e Ikemetseng, Botsofali bo Potlakileng, Kenyelletso ea Aterese ea Static Unicast / Multicast, QoS / Tlhokomelo ea Boema-kepe (802.1D/p), TOS/DSCP Prioritization, Interface Trust Mode, CoS Queue Management, IP Ingress DiffServ Classification le Sepolesa, IP Egress DiffServ Classification / Max-Queue-Queueliation. Lethathamo la Bandwidth, Phallo ea Phallo (802.3X), Egress Interface Shaping, Ingress Storm Protection, Jumbo Frames, VLAN (802.1Q), VLAN e thehiloeng ho Protocol, VLAN e sa tsebeng Mode, GARP VLAN Registration Protocol (GVRP), Voice VLAN, MAC-based VLANcast, IP subnetGA Protocol RP, IP subnet RP. IGMP Snooping/Querier per VLAN (v1/v2/v3), Unknown Multicast Filtering, Multiple VLAN Registration Protocol (MVRP), Multiple MAC Registration Protocol (MMRP), Multiple Registration Protocol (MRP), Layer 2 Loop Protection
Tlhokahalo: HIPER-Ring (Ring Switch), HIPER-Ring over Link Aggregation, Link Aggregation with LACP, Link Backup, Media Redundancy Protocol (MRP) (IEC62439-2), MRP over Link Aggregation, Redundant Network Coupling, Sub Ring Manager, RSTP 802.1D-EC16244, MSTP 802.1D-EC16244 (802.1Q), Balebeli ba RSTP, VRRP, Tracking ea VRRP, HiVRRP (lintlafatso tsa VRRP)
Tsamaiso: Dual Software Image Support, TFTP, SFTP, SCP, LLDP (802.1AB), LLDP-MED, SSHv2, V.24, HTTP, HTTPS, Traps, SNMP v1/v2/v3, Telnet, DNS Client, OPC-UA Server
 Tlhahlobo: Tlhokomeliso ea Khohlano ea Aterese ea Tsamaiso, Tsebiso ea MAC, Khokahano ea Lets'oao, Pontšo ea Boemo ba Sesebelisoa, TCPDump, LEDs, Syslog, Ho Rengoa ho sa Feleng ho ACA, Tsebiso ea lengolo-tsoibila, Tlhokomelo ea Boema-kepe ka Auto-Disable, Tlhahlobo ea Flap ea Khokahano, Tlhahlobo e Felletseng, Teko ea Duplex Mismatch, Lebelo la Link le Duplex Mismatch, RMON Mismatch,1 1:1, Port Mirroring 8:1, Port Mirroring N:1, RSPAN, SFLOW, VLAN Mirroring, Port Mirroring N:2, Information System, Boitlhahlobo ka Cold Start, Copper Cable Test, SFP Management, Configuration Check Dialog, Switch Dump, Snapshot Configuration Feature
 Tlhophiso: Phetoho e Ikemetseng (Roll-back), Configuration Fingerprint, Text-based Configuration File (XML), BOOTP/DHCP Client e nang le Auto-Configuration, DHCP Server: per Port, DHCP Server: Pools per VLAN, AutoConfiguration Adapter ACA31 (SD card), AutoConfiguration Adapter2sDiscover2,USB,USB Recovery ACA2,USB Khetho ea 82, Sebopeho sa Taelo ea Taelo (CLI), CLI Scripting, Tšehetso e feletseng ea MIB, Taolo e thehiloeng ho Websaete, Thuso e Senyehileng ka Moelelo.
  

Tshireletso:

Ts'ireletso ea Boema-kepe e thehiloeng ho MAC, Port-based Access Control e nang le 802.1X, VLAN e sa netefatsoang, Seva e Kopanetsoeng ea netefatso (IAS), Kabelo ea RADIUS VLAN, Kabelo ea Leano la RADIUS, netefatso ea bareki ba bangata ka Port, MAC Authentication Bypass, DHCP Snooping, IPS Mohloli oa Mohloli oa Mohloli oa Mohloli oa IPS Thibelo, LDAP, Ingress MAC-based ACL, Egress MAC-based ACL, Ingress IPv4-based ACL, Egress IPv4-based ACL, Time-based ACL, VLAN-based ACL, Ingress VLAN-based ACL, Egress VLAN-based ACL, ACL Flow-based Limiting, Access to Management e thibetsoe ke Trail Logging In VLAN, ACL Tsamaiso ea Setifikeiti, phihlello ea taolo e thibetsoeng, Banner ea Tšebeliso e Nepahetseng, Leano la Password la Configurable, Palo e Lokisitsoeng ea Maiteko a ho Kena, Ho rema lifate tsa SNMP, Maemo a Tloaelehileng a Mangata, Taolo ea Basebeletsi ba Sebaka, Bopaki ba Remote ka RADIUS, Ho notlela Ak'haonte ea Mosebelisi, Phetoho ea password ha u kena ka lekhetlo la pele.
Khokahano ea nako: PTPv2 Transparent Clock mehato e 'meli, PTPv2 Boundary Clock, Buffered Real Time Clock, SNTP Client, SNTP Server
Tse fapaneng: Manual Cable Crossing, Port Power Down

 

 

 Tsela:

IP/UDP Helper, Full Wire-Speed ​​Routing, Port-based Router Interfaces, VLAN-based Router Interfaces, Loopback Interface, ICMP Filter, Net-directed Broadcasts, OSPFv2, RIP v1/v2, ICMP Router Discovery (IRDP), Equal Cost Multiple Pathnicast (ECMP), Routic Routic Pathnicast (ECMP) IGMP v1/v2/v3, IGMP Proxy (Multicast Routing), DVMRP, PIM-DM (RFC3973), PIM-SM / SSM (RFC4601)

Multicast routing: DVMRP, PIM-DM (RFC3973), PIM-SM / SSM (RFC4601)

 

Ambientmaemo

Thempereichara ea ho sebetsa: 0-+60 °C
Mocheso oa polokelo/sepalangoang: -40-+70 °C
Mongobo o amanang (o sa nyenyefatseng): 10-95 %

 

Mechini kaho

Litekanyo (WxHxD): 480 mm x 88 mm x 445 mm
Ho hlongoa: 19 "khabinete ea taolo
Sehlopha sa tšireletso: IP20

 

 

Mefuta e fapaneng

Ntho #

Mofuta

942318002

DRAGON MACH4000-52G-L3A-UR

 

 

Hirschmann DRAGON MACH4000 Series Mehlala e Fumanehang

DRAGON MACH4000-48G+4X-L2A

DRAGON MACH4000-48G+4X-L3A-UR

DRAGON MACH4000-48G+4X-L3A-MR

DRAGON MACH4000-52G-L2A

DRAGON MACH4000-52G-L3A-UR

DRAGON MACH4000-52G-L3A-MR


  • E fetileng:
  • E 'ngoe:

  • Ngola molaetsa wa hao mona mme o re romele wona

    Lihlahisoa tse amanang

    • Hirschmann MIPP/AD/1L3P Modular Industrial Patch configurator

      Hirschmann MIPP/AD/1L3P Modular Industrial Pac...

      Tlhaloso ea Sehlahisoa Sehlahisoa: MIPP/AD/1L3P/XXXX/XXXX/XXXX/XXXX/XXXX/XX Configurator: MIPP - Modular Industrial Patch Panel configurator Tlhaloso ea Sehlahisoa MIPP™ ke ho felisoa ha indasteri le ho patching panel e etsang hore likhoele li felisoe le ho hokahana le lisebelisoa tse sebetsang joalo ka li-switch. Moralo oa eona o matla o sireletsa likhokahano hoo e batlang e le ts'ebeliso efe kapa efe ea indasteri. MIPP™ e tla joalo ka Fiber Splice Box, ...

    • Hirschmann MSP40-00280SCZ999HHE2A MICE Switch Power configurator

      Hirschmann MSP40-00280SCZ999HHE2A Litoeba Switjha P...

      Tlhaloso Sehlahisoa: MSP40-00280SCZ999HHE2AXX.X.XX Configurator: MSP - MICE Switch Power configurator Tlhaloso ea Sehlahisoa Tlhaloso ea Modular Full Gigabit Ethernet Industrial Switch for DIN Rail, Fanless design , Software HiOS Layer 2 Advanced Software Version HiOS 10.0.00 mofuta oa Ethernet Port4 kakaretso ea Ethernet ea mofuta oa 2 Likou tsa 2.5 Gigabit Ethernet: 4 (Likou tsa Gigabit Ethernet ka kakaretso: 24; 10 Gigabit Ethern ...

    • Hirschmann MM3 – 2FXS2/2TX1 Mojule oa litaba

      Hirschmann MM3 – 2FXS2/2TX1 Mojule oa litaba

      Mofuta oa Tlhaloso: MM3-2FXS2/2TX1 Nomoro ea Karolo: 943762101 Mofuta oa boema-kepe le bongata: 2 x 100BASE-FX, likhoele tsa SM, li-sockets tsa SC, 2 x 10/100BASE-TX, likhoele tsa TP, li-sockets tsa RJ45, auto-crossing, auto-cross of TP-linegotiation 0-100 Single mode fiber (SM) 9/125 µm: 0 -32.5 km, 16 dB link budget ho 1300 nm, A = 0.4 dB/km, 3 dB reserve, D = 3.5 ...

    • Hirschmann SFP GIG LX / LC SFP Module

      Hirschmann SFP GIG LX / LC SFP Module

      Tlhaloso ea Sehlahisoa Mofuta oa Tlhaloso ea Sehlahisoa: SFP-GIG-LX/LC Tlhaloso: SFP Fiberoptic Gigabit Ethernet Transceiver SM Part Number: 942196001 Mofuta oa boema-kepe le bongata: 1 x 1000 Mbit/s le LC sehokelo Bogolo ba Netweke - bolelele ba thapo Fiber mode Single mode (SM) 9/125 125 km3 µm3 Bunkt µm3 µm3 Bunkt µm3 nm = 0 - 10.5 dB ;

    • Hirschmann RS20-1600T1T1SDAPHH Managed Switch

      Hirschmann RS20-1600T1T1SDAPHH Managed Switch

      Tlhaloso Sehlahisoa: Hirschmann Hirschmann RS20-1600T1T1SDAPHH Configurator: RS20-1600T1T1SDAPHH Tlhaloso ea Sehlahisoa Tlhaloso E laoloang Fast-Ethernet-Switch bakeng sa lebenkele la terene la DIN-le-pele-pele, moralo o se nang fan; Software Layer 2 Professional Part Number 943434022 Mofuta oa Port le bongata ba likou tse 8 ka kakaretso: 6 x standard 10/100 BASE TX, RJ45; Uplink 1: 1 x 10/100BASE-TX, RJ45 ; Uplink 2: 1 x 10/100BASE-TX, R...

    • Hirschmann BRS20-8TX/2FX (Khoutu ea sehlahisoa: BRS20-1000M2M2-STCY99HHSESXX.X.XX) Switch

      Hirschmann BRS20-8TX/2FX (Khoutu ea sehlahisoa: BRS20-1...

      Letsatsi la Khoebo Tlhaloso ea Sehlahisoa Mofuta oa BRS20-8TX/2FX (Khoutu ea Sehlahisoa: BRS20-1000M2M2-STCY99HHSESXX.X.XX) Tlhaloso E Laoloang Phetoho ea Liindasteri bakeng sa DIN Rail, moralo o se nang fan Fast Ethernet Type Software Version HiOS10.0.00 Karolo ea Karolo 942170004 ka kakaretso ea mofuta oa Port1 x 8 10/100BASE TX / RJ45; 2x 100Mbit / s fiber; 1. Uplink: 1 x 100BASE-FX, MM-SC ; 2. Uplink: 1 x 100BAS...