• hlooho_banner_01

Hirschmann DRAGON MACH4000-48G+4X-L3A-UR Switch

Tlhaloso e Khutšoanyane:

Fetola Gigabit Ethernet Backbone Backbone e fihlang ho 48x GE + 4x 2.5/10 GE likoung, moralo oa modular, fan unit e kentsoe, liphanele tse foufetseng bakeng sa karete ea mohala le lisebelisoa tsa phepelo ea matla li kenyellelitsoe, likarolo tse tsoetseng pele tsa Layer 3 HiOS, routing ea unicast.


Lintlha tsa Sehlahisoa

Li-tag tsa Sehlahisoa

Letsatsi la Khoebo

 

Sehlahisoatlhaloso

Mofuta: DRAGON MACH4000-48G+4X-L3A-UR
Lebitso: DRAGON MACH4000-48G+4X-L3A-UR
Tlhaloso: Fetola Gigabit Ethernet Backbone Switch e nang le phepelo ea motlakase e sa sebetseng ka hare ho fihla ho 48x GE + 4x 2.5/10 GE likoung, moralo oa modular le likarolo tse tsoetseng pele tsa Layer 3 HiOS, routing e le 'ngoe.
Software Version: HiOS 09.0.06
Nomoro ea Karolo: 942154002
Mofuta oa boema-kepe le bongata: Likou ka kakaretso li fihla ho 52, Likou tsa motheo tsa 4 tse tsitsitseng: 4x 1 / 2.5 / 10 GE SFP +, Modular: 48x FE / GE likoung tse atolositsoeng ka li-module tse 'nè tsa mecha ea litaba, 12x FE / GE likoung ka module.

 

Hape Li-interface

V.24 segokahanyi: 1 x RJ45 sokete
Slot ea karete ea SD: 1 x ho hokela adaptara ea auto-configuration ACA31 (SD)
Sehokelo sa USB: 1 x USB ho hokela adaptara ea boiketsetso ea ACA22-USB

 

Matladitlhoko

Voltage e sebetsang:

PSU unit input: 100 - 240 V AC; switjha e ka sebetsoa ka li-unit tsa PSU tse 1 kapa tse 2 tse ka nkeloang sebaka (tse tla laeloa ka thoko)

Tšebeliso ea matla:

80 W (ho kenyeletsoa li-transceivers tsa SFP + 1 PSU + Fan module)

 

Software

 

 

Fetoha:

Ho Ithuta ka VLAN e Ikemetseng, Botsofali bo Potlakileng, Kenyelletso ea Aterese ea Static Unicast / Multicast, QoS / Tlhokomelo ea Boema-kepe (802.1D/p), TOS/DSCP Prioritization, Interface Trust Mode, CoS Queue Management, IP Ingress DiffServ Classification le Sepolesa, IP Egress DiffServ Classification / Max-Queue-Queueliation. Lethathamo la Bandwidth, Phallo ea Phallo (802.3X), Egress Interface Shaping, Ingress Storm Protection, Jumbo Frames, VLAN (802.1Q), VLAN e thehiloeng ho Protocol, VLAN e sa tsebeng Mode, GARP VLAN Registration Protocol (GVRP), Voice VLAN, MAC-based VLANcast, IP subnetGA Protocol RP, IP subnet RP. IGMP Snooping/Querier per VLAN (v1/v2/v3), Unknown Multicast Filtering, Multiple VLAN Registration Protocol (MVRP), Multiple MAC Registration Protocol (MMRP), Multiple Registration Protocol (MRP), Layer 2 Loop Protection
Tlhokahalo: HIPER-Ring (Ring Switch), HIPER-Ring over Link Aggregation, Link Aggregation with LACP, Link Backup, Media Redundancy Protocol (MRP) (IEC62439-2), MRP over Link Aggregation, Redundant Network Coupling, Sub Ring Manager, RSTP 802.1D-EC16244, MSTP 802.1D-EC16244 (802.1Q), Balebeli ba RSTP, VRRP, Tracking ea VRRP, HiVRRP (lintlafatso tsa VRRP)
Tsamaiso: Dual Software Image Support, TFTP, SFTP, SCP, LLDP (802.1AB), LLDP-MED, SSHv2, V.24, HTTP, HTTPS, Traps, SNMP v1/v2/v3, Telnet, DNS Client, OPC-UA Server
 

Tlhahlobo:

Tlhokomeliso ea Khohlano ea Aterese ea Tsamaiso, Tsebiso ea MAC, Khokahano ea Lets'oao, Pontšo ea Boemo ba Sesebelisoa, TCPDump, LEDs, Syslog, Ho Rengoa ho sa Feleng ho ACA, Tsebiso ea lengolo-tsoibila, Tlhokomelo ea Boema-kepe ka Auto-Disable, Tlhahlobo ea Flap ea Khokahano, Tlhahlobo e Felletseng, Teko ea Duplex Mismatch, Lebelo la Link le Duplex Mismatch, RMON Mismatch,1 1:1, Port Mirroring 8:1, Port Mirroring N:1, RSPAN, SFLOW, VLAN Mirroring, Port Mirroring N:2, Information System, Boitlhahlobo ka Cold Start, Copper Cable Test, SFP Management, Configuration Check Dialog, Switch Dump, Snapshot Configuration Feature
 

Tlhophiso:

Phetoho e Ikemetseng (Roll-back), Configuration Fingerprint, Text-based Configuration File (XML), BOOTP/DHCP Client e nang le Auto-Configuration, DHCP Server: per Port, DHCP Server: Pools per VLAN, AutoConfiguration Adapter ACA31 (SD card), AutoConfiguration Adapter2sDiscover2,USB,USB Recovery ACA2,USB Khetho ea 82, Sebopeho sa Taelo ea Taelo (CLI), CLI Scripting, Tšehetso e feletseng ea MIB, Taolo e thehiloeng ho Websaete, Thuso e Senyehileng ka Moelelo.
 

 

Tshireletso:

Ts'ireletso ea Boema-kepe e thehiloeng ho MAC, Port-based Access Control e nang le 802.1X, VLAN e sa netefatsoang, Seva e Kopanetsoeng ea netefatso (IAS), Kabelo ea RADIUS VLAN, Kabelo ea Leano la RADIUS, netefatso ea bareki ba bangata ka Port, MAC Authentication Bypass, DHCP Snooping, IPS Mohloli oa Mohloli oa Mohloli oa Mohloli oa IPS Thibelo, LDAP, Ingress MAC-based ACL, Egress MAC-based ACL, Ingress IPv4-based ACL, Egress IPv4-based ACL, Time-based ACL, VLAN-based ACL, Ingress VLAN-based ACL, Egress VLAN-based ACL, ACL Flow-based Limiting, Access to Management e thibetsoe ke Trail Logging In VLAN, ACL Tsamaiso ea Setifikeiti, phihlello ea taolo e thibetsoeng, Banner ea Tšebeliso e Nepahetseng, Leano la Password la Configurable, Palo e Lokisitsoeng ea Maiteko a ho Kena, Ho rema lifate tsa SNMP, Maemo a Tloaelehileng a Mangata, Taolo ea Basebeletsi ba Sebaka, Bopaki ba Remote ka RADIUS, Ho notlela Ak'haonte ea Mosebelisi, Phetoho ea password ha u kena ka lekhetlo la pele.
Khokahano ea nako: PTPv2 Transparent Clock mehato e 'meli, PTPv2 Boundary Clock, Buffered Real Time Clock, SNTP Client, SNTP Server
Tse fapaneng: Manual Cable Crossing, Port Power Down
Tsela: IP/UDP Helper, Full Wire-Speed ​​Routing, Port-based Router Interfaces, VLAN-based Router Interfaces, Loopback Interface, ICMP Filter, Net-directed Broadcasts, OSPFv2, RIP v1/v2, ICMP Router Discovery (IRDP), Equal Cost Multiple Pathnicast (ECMP), Routic Routic Pathnicast (ECMP) IGMP v1/v2/v3, IGMP Proxy (Multicast Routing)

 

 

Ambientmaemo

MTBF (Telecordia SR-332 Taba ea 3) @ 25°C:  

1 281 583 h

Thempereichara ea ho sebetsa: 0-+60 °C
Mocheso oa polokelo/sepalangoang: -40-+70 °C
Mongobo o amanang (o sa nyenyefatseng): 10-95 %

 

Mechini kaho

Litekanyo (WxHxD): 480 mm x 88 mm x 445 mm
Ho hlongoa: 19 "khabinete ea taolo
Sehlopha sa tšireletso: IP20

 

Litumello

Maemo a Motheo: C-Tick, CE, EN61131
Tšireletseho ea lisebelisoa tsa taolo ea indasteri: cUL61010-1/-2-201, EN60950-1
Lipalangoang: EN 50121-4

 

Mefuta e fapaneng

Ntho #

Mofuta

942154002

DRAGON MACH4000-48G+4X-L3A-UR

 

Hirschmann DRAGON MACH4000 Series Mehlala e Fumanehang

DRAGON MACH4000-48G+4X-L2A

DRAGON MACH4000-48G+4X-L3A-UR

DRAGON MACH4000-48G+4X-L3A-MR

DRAGON MACH4000-52G-L2A

DRAGON MACH4000-52G-L3A-UR

DRAGON MACH4000-52G-L3A-MR

 

 


  • E fetileng:
  • E 'ngoe:

  • Ngola molaetsa wa hao mona mme o re romele wona

    Lihlahisoa tse amanang

    • Hirschmann GRS1042-AT2ZSHH00Z9HHSE3AMR GREYHUND 1040 Gigabit Switch

      Hirschmann GRS1042-AT2ZSHH00Z9HHSE3AMR GREYHOUN...

      Selelekela Moralo o feto-fetohang oa li-switches tsa GREYHOUND 1040 o etsa hore sena e be sesebelisoa sa marang-rang se nang le bopaki ba nako e tlang se ka fetohang hammoho le bandwidth ea marang-rang le litlhoko tsa matla. Ka ho tsepamisitse maikutlo ho bongata ba marang-rang tlas'a maemo a thata a indasteri, li-switches tsena li na le lisebelisoa tsa motlakase tse ka fetoloang tšimong. Hape, li-module tse peli tsa media li u thusa ho fetola palo ea koung ea sesebelisoa le mofuta oa eona -...

    • Hirschmann GRS106-16TX/14SFP-2HV-3AUR GREYHUND Switch

      Hirschmann GRS106-16TX/14SFP-2HV-3AUR GREYHUND...

      Letsatsi la Khoebo Tlhaloso ea Sehlahisoa Mofuta oa GRS106-16TX/14SFP-2HV-3AUR (Khoutu ea sehlahisoa: GRS106-6F8F16TSGGY9HHSE3AURXX.X.XX) Tlhaloso GREYHOUND 105/106 Series, Managed Industrial Switch, ho latela moralo o se nang fan, EE2 "Mount 19" 6x1/2.5/10GE +8x1/2.5GE +16xGE Design Software Version HiOS 9.4.01 Karolo ea Nomoro 942287016 Mofuta oa boema-kepe le bongata 30 Ports ka kakaretso, 6x GE/2.5GE/10GE SFP(+) slot + 8x GE/2.51 SFP + 2.51 SFP ...

    • Hirschmann BRS40-0020OOOO-STCZ99HHSES Phetoho

      Hirschmann BRS40-0020OOOO-STCZ99HHSES Phetoho

      Commerial Date Configurator Description Hirschmann BOBCAT Switch ke ea pele ea mofuta oa eona ea ho nolofalletsa puisano ea nako ea nnete e sebelisang TSN. Ho ts'ehetsa ka nepo litlhoko tse ntseng li eketseha tsa puisano ea nako ea nnete maemong a indasteri, mokokotlo o matla oa marang-rang oa Ethernet o bohlokoa. Liphetoho tsena tse laoloang ke komporo li lumella bokhoni bo atolositsoeng ba bandwidth ka ho fetola li-SFP tsa hau ho tloha ho 1 ho isa ho 2.5 Gigabit - e sa hlokeng phetoho ho sesebelisoa ...

    • Hirschmann MIPP/AD/1L3P Modular Industrial Patch configurator

      Hirschmann MIPP/AD/1L3P Modular Industrial Pac...

      Tlhaloso ea Sehlahisoa Sehlahisoa: MIPP/AD/1L3P/XXXX/XXXX/XXXX/XXXX/XXXX/XX Configurator: MIPP - Modular Industrial Patch Panel configurator Tlhaloso ea Sehlahisoa MIPP™ ke ho felisoa ha indasteri le ho patching panel e etsang hore likhoele li felisoe le ho hokahana le lisebelisoa tse sebetsang joalo ka li-switch. Moralo oa eona o matla o sireletsa likhokahano hoo e batlang e le ts'ebeliso efe kapa efe ea indasteri. MIPP™ e tla joalo ka Fiber Splice Box, ...

    • Hirschmann MACH4002-24G-L3P 2 Media Slots Gigabit Backbone Router

      Hirschmann MACH4002-24G-L3P 2 Media Slots Gigab...

      Selelekela MACH4000, modular, e laoloang Industrial Backbone-Router, Layer 3 Switch with Software Professional. Tlhaloso ea Sehlahisoa MACH 4000, modular, e laoloang Industrial Backbone-Router, Layer 3 Switch with Software Professional. Ho fumaneha Letsatsi la ho Qetela la Odara: La 31 Hlakubele 2023 Mofuta oa Boema-kepe le bongata ho fihla ho 24...

    • Hirschmann MSP30-08040SCZ9MRHHE3A MSP30/40 Switch

      Hirschmann MSP30-08040SCZ9MRHHE3A MSP30/40 Switch

      Tlhaloso Sehlahisoa: MSP30-08040SCZ9MRHHE3AXX.X.XX Configurator: MSP - MICE Switch Power configurator Technical Specifications Product Description Modular Gigabit Ethernet Industrial Switch for DIN Rail, Fanless design , Software HiOS Layer 3 Advanced Software Version HiOS 09.0.08 Portquantity total: Li-port tsa Gigabit Ethernet: 4 More Interfaces Power s...